The split-type ultrasonic level detector comprises a sensor and a converter. The sensor is mounted at the measurement point, while the converter can be placed remotely in a control room or another convenient location, connected to the sensor via a cable.

Principle of the WKL-U02-S ultrasonic level detector
Install height G: ( probe to the height of the tank bottom)
Liquid level H: ( level or material level height)
Air distance L: (probe to test surface area)
Blanking distance C: (a small area below the sensor)
Instrument range d: (generally from zero to the highest plane, only linearly corresponding to output P)
Formula:
1、Ranging:L=S*T/2; S=331.45+0.61*n℃
2、Level:H=G-L
3、Output: P=H/d*16+4 or P=L/d*16+4 (Note: P output current in mA)